Skip to content

Hydrogenation

Heating oil to converter temperature, and cooling the hardened product that comes out.

Recommended type

Fully Welded Plate & Frame Heat Exchanger

The reaction itself belongs to the converter; the plate duties are the heat into it and the heat out of it. Nickel catalyst fines carried in the product stream are what decide the channel and the cleaning regime on the cooling side. Viton on any gasketed stage, because converter temperature and hot hardened oil together are more than a nitrile compound will take.

A fully welded plate pack in its frame, built for a condensing duty. No gasket anywhere in the thermal section, so temperature stops being the limit.
A fully welded plate pack in its frame, built for a condensing duty. No gasket anywhere in the thermal section, so temperature stops being the limit.

Also suitable