Skip to content

Bleaching

Raising oil to bleacher temperature, and cooling the filtered oil that leaves it.

Recommended type

Standard Gasketed Plate Heat Exchanger

The inlet side is a clean oil duty. What decides the selection is the outlet: bleaching earth carried through a leaking filter will find the narrowest channel in the plant, so the filtration ahead of the exchanger is part of the specification. Where the unit is gasketed, specify Viton: hot oil at bleacher temperature is what a nitrile gasket swells and hardens in, and the replacement interval is the real cost.

Gasketed units on their frames, built and waiting for despatch. The painted carbon-steel frame is what a gasketed plate heat exchanger normally looks like; the plate pack between the tie bars is stainless, and it is the pack, not the frame, that touches the process.
Gasketed units on their frames, built and waiting for despatch. The painted carbon-steel frame is what a gasketed plate heat exchanger normally looks like; the plate pack between the tie bars is stainless, and it is the pack, not the frame, that touches the process.

Also suitable