Spin finish emulsion cooling
Holding the spin finish emulsion at temperature before it reaches the applicators.
Recommended type
Standard Gasketed Plate Heat Exchanger
An oil-in-water emulsion that will drop out and film the plate if it is sheared hard or run too cold, so the plate pattern is chosen for a gentle channel rather than maximum turbulence. Wide gap where the emulsion carries fibre debris.