SynergizingTechnologies
Sustainable Technologies towards a greener future.
Plate heat exchangers — gasketed, semi-welded and fully welded — and non-OEM plates and gaskets for Alfa Laval, Kelvion, Sondex, Tranter, APV and more.
Sustainable Technologies towards a greener future.
Choose your industry to narrow down to the duty.
Jacket water cooling
Cooling the main and auxiliary engine high-temperature jacket water circuit against the low-temperature loop.
Also called: jacket water cooler, JCW cooler, HT cooler, high temperature fresh water cooler.
Recommended type
Standard Gasketed Plate Heat Exchanger
Fresh water on both sides, so the duty is clean and a gasketed pack gives the close approach in the smallest footprint an engine room has to offer. The engine maker sets the jacket outlet temperature; holding it steadily across the load range matters more than the peak duty. Gasket compound is chosen for treated cooling water at jacket temperature.